Siemens TPS3L0530X2 TPS3 05 Type 2 Internal Low Voltage Standard Mode Surge Protective Device With Surge Counter, 600Y/347 VAC, 47 to 63 Hz, 200 kA SCCR, 3 Phase

Siemens_TPS3A0510X2.jpg

Description

Siemens Surge Protective Device, Type 2 Internal Low Voltage Standard Mode, Series: TPS3 05, 600Y/347 VAC Electrical Rating, 47 to 63 Hz Frequency, 4+G Wires, 200 kA Short Circuit, 300 kA Peak Surge Current, 20 kA Nominal Discharge, Modes of Protection: L-N, L-G, N-G, L-L, <0.5 ns Response, LED/Audible Alarm Indicator, 3 ph, Environmental Conditions: -15 to 140 deg F Operating, 1 to 95% Non-Condensing Relative Humidity, NEMA 1 Enclosure, Wall Mounting, Load Terminal, Galvanneal Steel, Gray, 10 in L x 17 in W x 6 in H Dimensions

Siemens TPS3 05 surge protective devices are designed for integration within our P4 and P5 panelboards as well as distribution switchboards. The TPS3 01 SPDs feature Ground Integrity Monitoring (GIM) diagnostics.

Features

  • TPS TranSafe enabled - our patented TranSafe fault current protection circuitry provides peace of mind that your electronic loads are protected and that your electrical system will not go down due to SPD fault control operations
  • Integral or internally mounted for optimized protection - internal surge protection dramatically reduces installation impedance allowing for superior installed suppressed voltage capabilities
  • SAD/MOV hybrid suppression - for mission critical applications needing the absolute best suppressed voltage, our hybrid SAD/MOV suppressors combine tight clamping technology with integrated suppression, delivering the strongest installed protection capabilities available
  • Low suppressed voltage ratings - TPS family offers some of the lowest UL 1449 listed suppressed voltage ratings available, meaning your electronics will last longer when compared to SPDs with higher ratings
  • UL 96A lightning protection master labeling compliant
  • Large block, individually fused, thermally protected, 50 kA MOVs
  • Every MOV is monitored, including N-G
  • Mounts internal to P4, P5 panelboards and distribution switchboards
  • All UL required OCP and safety coordination included - type 1 SPDs intended for line or load side of main disconnect, type 2 SPDs intended for load side of main disconnect
  • Standard monitoring - LED indicators, dry contacts, audible alarm with silence switch and test button, internal rotary disconnect switch
  • 5000 hits repetitive impulse
  • 1500 V L-N, 1500 V L-G, 1500 V N-G, 2500 V L-L voltage protection rating

Specifications

GTIN: 00804766273247

UNSPSC: 39121610

Alternative Part Number: 13855467

Color
Gray
Dimensions
10 in L x 17 in W x 6 in H
Electrical Ratings
600Y/347 VAC
Enclosure Type
NEMA 1
Environmental Conditions
-15 to 140 deg F Operating, 1 to 95% Non-Condensing Relative Humidity
Frequency Rating
47 to 63 Hz
Indicator Type
LED/Audible Alarm
Material
Galvanneal Steel
Modes of Protection
L-N, L-G, N-G, L-L
Mounting Type
Wall
Nominal Discharge Current
20 kA
Number of Wires
4+G
Peak Surge Current
300 kA
Phase
3
Response Time
<0.5 ns
Series
TPS3 05
Short Circuit Current Rating
200 kA
Terminal Type
Load
Type
Type 2 Internal Low Voltage Standard Mode
Width
3.5 in