Siemens TPS3AL1230SXD2 TPS3 L12 Type 2 External Low Voltage True 10-Mode Protection Surge Protective Device With Surge Counter and Internal Rotary Disconnect Switch, 120/240 VAC, 47 to 63 Hz, 100 kA SCCR, 1 Phase

Siemens TPS3AL1230SXD2 TPS3 L12 Type 2 External Low Voltage True 10-Mode Protection Surge Protective Device With Surge Counter and Internal Rotary Disconnect Switch, 120/240 VAC, 47 to 63 Hz, 100 kA SCCR, 1 Phase
MPN TPS3AL1230SXD2
ASPN SIETPS3AL1230SXD2
UPC 804766261183
Description
Features
- TPS TranSafe enabled - our patented TranSafe fault current protection circuitry provides peace of mind that your electronic loads are protected and that your electrical system will not go down due to SPD fault control operations
- Flexibility - whether you need compact design or extra redundancy, Siemens TPS family of hard wired TVSS/SPDs will have a solution to meet your needs
- Low suppressed voltage ratings - TPS family offers some of the lowest UL 1449 listed suppressed voltage ratings available, meaning your electronics will last longer when compared to SPDs with higher ratings
- UL 96A lightning protection master labeling compliant
- Every MOV is monitored, including N-G
- Large block, individually fused, thermally protected, 50 kA MOVs
- Mounts external to electrical distribution equipment - recommend for line side or load side applications
- All UL required OCP and safety coordination included - type 1 SPDs intended for line or load side of main disconnect, type 2 SPDs intended for load side of main disconnect
- Solid state bi-directional operation
- Standard monitoring - LED indicators, ground integrity monitoring diagnostics, dry contacts, audible alarm with silence switch and test button
- 5000 hits repetitive impulse
- Directly connected discrete protection elements between all possible modes providing true 10-mode protection
- 700 V L-N, 700 V L-G, 700 V N-G, 1000 V L-L voltage protection rating
Specifications
GTIN: 00804766261183
UNSPSC: 39121610
Country of Origin: United States of America (the)
Frequency Rating | 47 to 63 Hz |
---|---|
Nominal Discharge Current | 20 kA |
Enclosure Type | NEMA 4X |
Short Circuit Current Rating | 100 kA |
Dimensions | 12 in L x 12 in W x 7 in H |
Mounting Type | Wall |
Phase | 1 |
Environmental Conditions | -15 to 140 deg F Operating, 0 to 95% Non-Condensing Relative Humidity |
BABA Compliant | No |
Response Time | <1 ns |
Electrical Ratings | 120/240 VAC |
Indicator Type | LED/Audible Alarm |
Material | Stainless Steel |
Series | TPS3 L12 |
Peak Surge Current | 300 kA |
Modes of Protection | L-N, L-G, N-G, L-L |
Color | Gray |
Number of Wires | 3+G |
Terminal Type | Load |
Type | Type 2 External Low Voltage True 10-Mode Protection |
Sold as | EACH |